Skip to main content
Port Pirie Regional Council · DA

31 Kingston Rd Port Pirie South, Development application

View on PlanSA (opens in a new tab)
Under assessment

Overview

Address
31 Kingston Rd Port Pirie South SA 5540
Application ID
26010803
Assessment pathway
Performance assessed
Public notice
Not stated
Proposal
This application is for the extension of an existing storage shed / home workshop at 31 Kingston Road, Port Pirie South, following the complete demolition and removal of an old, slightly smaller, low, flat roofed shed on the same site. Although the shed is proposed to be erected is close to the property boundary on its southern Drage street side, it will continue the line of the existing steel framed shed designed by Basic Steel and erected in 2008, and the gutter will remain within the boundary. Drage Street is essentially a service road – there are no homes facing the street on either side (south side is all open school grounds used for agricultural studies or maintenance work), and there are several existing sheds on property boundaries along the north side. Access Access will be provided from Drage St. via a 5m lift panel door. Most of the kerbing in front of the new door is already provided with a driveway entrance, apart from a metre or so at the eastern end. Given this access will be required very infrequently, no kerbing modifications are required. Cladding The roof will be Colorbond Custom Orb, in Classic Cream, per the existing shed to be extended. Wall sheeting will be Lysacht multiclad wall sheeting per the existing shed, similarly finished in Classic Cream. All doors, guttering, flashing etc. will similarly be finished in Colorbond Classic Cream. Structure All structural members shown on the drawings are the same as those employed in the Basic Steel designed shed to be extended, apart from the back-to back C section beam above the lift panel door. Note the existing west wall structure will form the greater part of the eastern side structure of the extension, however the existing west wall structure will remain in its entirety apart from cut-outs in the wall sheeting to allow for new member protrusions. The existing south-west column of the existing shed will have a strengthening plate welded into it behind the flange of the south wall beam of the extension (refer drawing). Footings The shed will be founded on a 150 mm reinforced concrete slab, thickened to 500mm deep under the columns and mullions for at least 150 mm in any direction from any fixing bolt. Columns will be fixed to the slab using M20*260mm chemset anchor bolts, and mullions will be fixed to the slab using M12*100 mm hex head masonry screws. Water Disposal All water collected from the shed to be demolished is directed into an existing 64kL underground tank as shown on the drawings. All water from the proposed shed extension will also be directed into this tank. The additional roof area will be 16.3m3, increasing collection by 408 L per 25mm rainfall. Structural Fixings As noted on drawings – M16 Flange Purlin Bolts to be torqued to 62Nm, M12 bolts for purlin and girt connections to be torqued to 30Nm.
Elements
Not listed
Zone
Suburban Neighbourhood Zone

Key dates

Lodged
27 October 2026
Public notice starts
N/A
Representations close
N/A
Decided
Not yet decided

Comments · 0

Loading...

Loading comments...